CADR Calculator for Construction & Renovation Dust

Find the minimum Clean Air Delivery Rate for your room.

Home renovation and construction generate extremely fine, hazardous dust. Drywall dust (calcium sulfate) is 1–10 μm, sawdust ranges from 1–100 μm, and silica dust from cutting tile or concrete is dangerously fine at 0.5–5 μm. These particles are not just annoying — they're a genuine health hazard.

During active renovation, dust generation is constant and heavy. Standard ACH recommendations don't apply — you need maximum air turnover. We recommend 8+ ACH during active construction, dropping to 5 ACH for the 2–4 week cleanup period afterward.

Critical: construction dust destroys filters fast. HEPA cartridges that normally last 8 months can clog in 2–4 weeks during heavy renovation. Budget for multiple filter replacements.

ACH: 7
Minimum CADR Required
240
CFM
Room: 180 sq ft · Vol: 1,440 cu ft
Dust CADR
240
CFM
Pollen CADR
240
CFM
Smoke CADR
240
CFM
🏠 Your room, to scale (top view)
180 ft² Purifier
15 ft × 12 ft floor plan · purifier placed in a corner
Filters all the air in your room per hour — about once every 15 min.
That's roughly a 17 m² bedroom-sized space.

📐 How CADR Is Calculated

Formula: CADR = (Sq Ft × Ceiling × ACH) ÷ 60

AHAM recommends ≥ 4.8 ACH. Allergies: 6 ACH. Smoke/Asthma: 8 ACH.

Recommended Air Purifiers

Based on 240 CFM minimum Smoke CADR:

✅ Next steps
Aim for an air purifier rated at least 240 CFM (smoke CADR 216 CFM) for this room.

💡 Tips for Construction Dust